…..Replace VCO2 2n5459 Transistor, VCO1 Oscillator Transistor pair, all 2n5459, 5172 & 5461.

Replace Key Bushings. Recap PSU. Calibrate.

SYNC ISSUE: Replace 2x 4011 ICs with original RCA brand.